Deployable maintenance shelter.

Maintenance, warehouse and fabric-roof accommodation configurations — erected, struck and re-used wherever the mission moves.

DMTSS
40-yr

service life (MILCON-equiv)

7 yrs

no maintenance intervention

40 × 100 ft

largest envelope

ISO compatible

ships in containers

What DMTSS brings to the mission.

Explore DMTSS
A DMTSS shelter on a sand compound with its full-width gable end open, showing an unobstructed internal span with material stacked along one side and no fixed fit-out

Purpose-built for deployment.

Why it’s different
Deployable, relocatable, multi-purpose tactical shelter suite — in a maintenance and warehouse configuration and a fabric-roof billeting configuration.
Read more

Easily relocated, erected, disassembled, transported and re-used. DMTSS-1 is the maintenance and warehouse building, up to 40 ft wide and 100 ft long, with a roller door and an unobstructed internal span. DMTSS-3 is the billeting, office and classroom building with a double-skin fabric roof, perimeter windows and a double door at each end. The hard-roof billeting configuration is now a product of its own — see Tactical Shelter.

A white insulated-panel DMTSS shelter seen from the corner on a new asphalt apron under a blue sky, its gable end carrying a roller-shutter door and a personnel door, the long flank running away to the left
A wall-mounted electrical enclosure on the outside of a DMTSS shelter with its door open, showing a certified mains switch-disconnector and circuit breaker, neatly terminated cabling and an earth bond, fixed to the ribbed insulated wall panel

Engineered, calculated and proof-tested.

How it’s built
Engineered to the wind, snow and code requirements of the deployment site.
Read more

Standards: fire-resistant PIR panels; engineered to the wind, snow and code requirements of the project — site figures on request. CONUS/OCONUS anchoring options (ground-screw and soil anchoring are not permitted in the USA).

Configurations: DMTSS-1 maintenance and warehouse; DMTSS-3 billeting, office and classroom with a fabric roof. Extreme-cold build-up available — demountable inner wall insulation, 3 × 100 mm mineral wool between ventilated voids, Uc 0.075 W/m²K.

Engineered in from the start.

Capabilities
Built into the base system — hover any capability for the detail.
  • Insulated envelope
  • Fire-resistant panels
  • Aluminium framework
  • CONUS / OCONUS anchoring

The engineering envelope.

Specifications
Use
Maintenance, warehouse
Width
20 / 30 / 40 ft (6.1 / 9.1 / 12.2 m)
Length
40 / 60 / 80 / 100 ft (12.2 / 18.3 / 24.4 / 30.5 m)
Roof
PIR sandwich panel, 60 mm
Doors
Roller door and personnel door
Site conditions
OCONUS gravel / CONUS concrete slab
Service life
40 years (MILCON-equivalent)
Maintenance
None required in the first 7 years
Options
Generator set
A completed DMTSS shelter on a marked asphalt apron under a clear sky, seen from the corner: white insulated wall panels, a gutter and downpipe along the eaves, a roller-shutter door and a personnel door in the gable end
Get in touch

Match a system to your mission.

Tell BANAIR what you need to store, move, shelter, support or train for. Engineering will route you to the right application, product family and next step in one business day.